SmartCT Soft Tissue Helical
Neuro imaging technology
  • Alternative product photograph
  • Product with accessory photograph
  • Standard product photograph
  • Philips SmartCT Helical movement

SmartCT Soft Tissue Helical

Neuro imaging technology
SmartCT Soft Tissue Helical creates CBCT images to help spot soft tissue changes in the Angio suite. The new protocol with dual-axis acquisition trajectory and improved reconstruction software results in images with improved image appearance compared to conventional cone beam acquisition techniques. SmartCT Soft Tissue Helical is our improved CBCT protocol for neurovascular care with a fast 8 secs trajectory, metal artifact and motion compensation algorithms to further improve image quality.

Clinical image gallery

Features
SmartCT empowers you to easily adopt 3D imaging in the lab
Despite the advantages of 3D imaging, it can still be considered difficult to perform by many users. To take the guesswork out of 3D acquisition, SmartCT provides step-by-step guidance and visual aids during acquisition to help easily acquire 3D images. 3D imaging can enhance diagnostic accuracy [1-3], support improved treatment outcomes[4-6] and increase procedural efficiency in the interventional lab [7].
SmartCT empowers you to easily adopt 3D imaging in the lab
Control advanced 3D visualization and measurement tools at tableside​
Using simple tablet gestures, you can carry out advanced measurements and visualizations on the touchscreen at tableside to study the disease in great detail. SmartCT 3D images can help reveal information not apparent on DSA images. This additional information may change diagnosis, treatment planning or treatment delivery, supporting better patient outcomes[4-9]. ​
Control advanced 3D visualization and measurement tools at tableside​
Automatic motion compensation for neuro helical​​
The Automatic motion compensation algorithm is a Helical Soft Tissue option, which the physician can use to salvage a CBCT soft tissue scan during which the patient had moved. During stroke procedures, the patient is not always sedated, and this often results in significant head motion, affecting the value of the 3D scan and often requiring a second scan. The automatic motion compensation algorithm takes the original scan and re-runs the reconstruction software to generate an improved volume.
Automatic motion compensation for neuro helical​​


Related products

  • SmartCT 3D visualization and measurement solution
    Philips Image Guided Therapy clinical application software SmartCT enriches our outstanding 3D interventional tools with clear guidance, designed to remove barriers to acquiring 3D images in the interventional lab. Once acquired, 3D images are automatically displayed within seconds on the touchscreen module in the corresponding rendering mode. On the same touchscreen, the user can easily control and interact with advanced 3D visualizations and measurement tools. SmartCT also brings advanced measurements and visualization to your fingertips for high image quality, supporting your diagnosis[1-3] and better patient treatment outcomes[4-6].​
  • Azurion 7 B20/15 Image Guided Therapy System Biplane
    Philips Azurion system allows you to perform a wide range of routine and complex interventional procedures easily and confidently with a unique user experience. Advanced capabilities integrated with an innovative system geometry support improved workflow, helping you to optimize your lab performance and provide superior care to your patients.
  • Azurion 7 M20 Image Guided Therapy System Monoplane Ceiling/Floor Mounted
    Experience outstanding interventional cardiac and vascular performance on the Azurion 7 Series with 20'' flat detector. This industry leading image-guided therapy solution supports you in delivering outstanding patient care and increasing your operational efficiency by uniting clinical excellence with workflow innovation. Seamlessly control all relevant applications from a single touch screen at table side, to help make fast, informed decisions in the sterile field.
  • Azurion 5 M20 Image Guided Therapy System Monoplane Ceiling/Floor Mounted
    Elevate your interventional capabilities with the Azurion 5 with 20'' flat detector. Your interventional teams benefit from superb consistency and efficiency as they perform diverse vascular and cardiac procedures. Seamlessly control all relevant applications at table side for a consistent user experience, excellent lab performance and patient care.
  • SmartCT Angio Advanced 3D visualization
    SmartCT Angio offers a 3D-RA (3D rotational angiography) acquisition protocol that provides extensive 3D visualization of bone and vessels based on a single contrast-enhanced rotational angiogram. Its high-resolution 3D reconstructions provide critical information about depth and the relationship of one vessel to another to support accurate assessment of bone and vasculature.
  • SmartCT Roadmap Live 3D image guidance tool
    SmartCT Roadmap facilitates interventions by providing live 3D image guidance that can be segmented to emphasize target vessel and lesions, aiding guidewire and catheter navigation through complex vessel structures. All controlled via the touch screen at the table.
  • SmartCT Soft Tissue CT-like visualization
    SmartCT Soft Tissue offers a Cone Beam CT (CBCT) acquisition technique augmented with step-by-step guidance, Advanced 3D visualization and measurement tools all accessible on the touch screen module at table side. To support you in acquiring CBCT images first-time right and to streamline your workflow, you are guided through key steps. Once the CBCT scan is successfully performed, the acquired 3D image is automatically displayed in the SmartCT 3D visualization tool with the adequate rendering settings and the 3D measurement tools tailored for the selected 3D protocol.
  • SmartCT Vaso High-resolution, contrast enhanced CBCT acquisition
    SmartCT Vaso enables high-contrast and high-resolution imaging of cerebral vasculature based on a 3D rotational scan and an intra-arterial contrast injection. This technique enhances the visualization of endovascular stents, flow diverters, or other devices, as well as vessel morphology down to the perforator level.
  • SmartCT Dual Viewer​ 3D volume comparison and fusion solution​
    SmartCT Dual Viewer can take any two volumes from the Azurion System, display them side by side and overlay them to create fusion images to support the physician in assessment and diagnosis and treatment planning (segmentation for example, manual feeder detection). Dual Viewer in SmartCT allows the user to view and manipulate the volumes at tableside without breaking sterility using the touchscreen module (TSM) or mouse and keyboard. There is also no need to switch applications because the entire workflow from 3D acquisition protocol selection to image viewing, manipulation, image overlay and postprocessing can be done in SmartCT and on the TSM.
  • SmartCT Dual Phase Cerebral Neuro imaging technology
    The Dual Phase Cerebral acquisition offers two consecutive contrast-enhanced cone beam CT scans of the brain. In the case of a stroke patient with a suspected large vessel occlusion, this type of acquisition allows identification of the vessel occlusion in the first phase, and the presence of collateral vessels in the second phase. This acquisition can be done with an intra-arterial as well as with intravenous contrast injection.
  • AneurysmFlow Cerebral aneurysm flow quantification
    Assessing impact of embolization devices, like flow diverters, on blood flow right after deployment is crucial. AneurysmFlow is designed to provide relevant information based on quantification of blood flow changes.
Disclaimer
* The user level of expertise required is described in the Instructions for Use as the Intended Operator Profile
SmartCT R3.0 is subject to regulatory clearance and may not be available in all markets. Contact your sales representative for more details.
1. Akkakrisee SA, Hongsakul KR. Percu-taneous transthoracic needle biopsy for pulmonary nodules: a retrospec-tive study of a comparison between C-arm cone-beam computed to-mography and conventional com-puted tomography guidance. Pol J Radiol.. 2020; 85(-): e309–e315
2. Jang H, Jung WS, Myoung SU, Kim JJ, Jang CK, Cho KC, Source Image Based New 3D Rotational Angiography for Differential Diagnosis between the In-fundibulum and an Internal Carotid Artery Aneurysm : Pilot Study. J Korean Neurosurg Soc, 2021. 64(5):726-731
3. Schernthaner et al., Delayed-Phase Cone-Beam CT Improves Detectability of Intrahepatic Cholangiocarcinoma During Conventional Transarterial Chemoembolization Cardiovasc Intervent Radiol , 38 (4), 929-36, 2015
4. Xiong, F., et al., Xper-CT combined with laser-assisted navigation radiofrequency thermocoagulation in the treatment of trigeminal neuralgia. Front Neu-rol, 2022. 13: p. 930902
5. Schott, P., et al., Radiation Dose in Prostatic Artery Embolization Using Cone-Beam CT and 3D Roadmap Software. J Vasc Interv Radiol, 2019. 30(9): p. 1452-1458
6. Rosi, A., et al., Three-dimensional rotational angiography improves mechanical thrombectomy recanalization rate for acute ischaemic stroke due to mid-dle cerebral artery M2 segment occlusions. Interv Neuroradiol, 2022: p. 15910199221145745
7. Ribo et al, Direct Transfer to Angiosuite to Reduce Door-To-Puncture Time in Thrombectomy for Acute Stroke, J Neurointerv Surg , 2018, 10 (3), 221-224
8. Fagan et al., MultiModality 3-dimensional image integration for Congenital Cardiac Catheterization. Methodist Debakey Cardiovasc J. 2014, 10 (2), 68-76
9. Hirotaka Hasegawa et al, Integration of rotational angiography enables better dose planning in Gamma Knife radiosurgery for brain arteriovenous malformations, J Neurosurg (Suppl) 129:17–25, 2018