Shielded-Lead-Set-Snap-AAMI Variation Group IEC ICU

Lead Set

Find similar products

Full color coded wire lead set with easy to manage wires. Packaged 1 set per bag. Replaces old M1613A lead set. Must be used with new trunk cable designs: M1668A, M1669A, M1663A, M1949A.

Specifications

ECG Lead Set
ECG Lead Set
Patient Application
  • Child; Adult
Application Site
  • Limb
Lead Set Length
  • 1.0 m (3.3')
Number of Leads
  • 3
Shielded
  • Yes
Electrode Attachment Method
  • Grabber
Color Coding
  • IEC
Product details
Product details
Use with Philips Healthcare Equipment
  • M3000A, M3001A, M3002A, M8102A, M8105A, M1001B, M1002B, 863063, 863064, 863065, 863066, 863068, 863077, M3535A, M3536A, M3536M, M4735A
Use with Non-Philips Healthcare Equipment
  • No
Product Category
  • ECG
Product Type
  • Lead Set
CE Certified
  • Yes
Single-Patient Use OR Multi-Patient Use
  • Multi-Patient Use
Package Weight
  • .180 kg
Packaging Unit
  • 1 lead set
Not manufactured with natural rubber latex
  • Yes
Minimum Shelf Life
  • None
Sterile OR Non-Sterile
  • Non-Sterile
Use with Other Supplies
  • M1669A
ECG Lead Set
ECG Lead Set
Patient Application
  • Child; Adult
Application Site
  • Limb
Product details
Product details
Use with Philips Healthcare Equipment
  • M3000A, M3001A, M3002A, M8102A, M8105A, M1001B, M1002B, 863063, 863064, 863065, 863066, 863068, 863077, M3535A, M3536A, M3536M, M4735A
Use with Non-Philips Healthcare Equipment
  • No
See all specifications
ECG Lead Set
ECG Lead Set
Patient Application
  • Child; Adult
Application Site
  • Limb
Lead Set Length
  • 1.0 m (3.3')
Number of Leads
  • 3
Shielded
  • Yes
Electrode Attachment Method
  • Grabber
Color Coding
  • IEC
Product details
Product details
Use with Philips Healthcare Equipment
  • M3000A, M3001A, M3002A, M8102A, M8105A, M1001B, M1002B, 863063, 863064, 863065, 863066, 863068, 863077, M3535A, M3536A, M3536M, M4735A
Use with Non-Philips Healthcare Equipment
  • No
Product Category
  • ECG
Product Type
  • Lead Set
CE Certified
  • Yes
Single-Patient Use OR Multi-Patient Use
  • Multi-Patient Use
Package Weight
  • .180 kg
Packaging Unit
  • 1 lead set
Not manufactured with natural rubber latex
  • Yes
Minimum Shelf Life
  • None
Sterile OR Non-Sterile
  • Non-Sterile
Use with Other Supplies
  • M1669A
  • Product may not be available in all geographies, please check with your Philips representative for complete portfolio availability.

You are about to visit a Philips global content page

Continue

You are about to visit a Philips global content page

Continue

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.