Respironics V680

Critical Care Ventilator

Discover Philips Respironics V680: the simple, clinically advanced way to provide your patients with reliable, high-performance ventilation across the continuum of care - without compromise.

Discover Philips Respironics V680: the simple, clinically advanced way to provide your patients with reliable, high-performance ventilation across the continuum of care - without compromise.

Performance with Flexibility

 

The V680 ventilator combines the fully featured life support capabilities of a critical care ventilator with our gold standard in noninvasive ventilation (NIV) technology. Find out why this breakthrough two-in-one ventilator should be your choice.

 

  • Switching from IV to NIV is fast and easy
  • For adult and pediatric* patients
  • Single- and Dual-limb circuits
  • Enhanced performance from our masks & circuits
*5-20kg
Enhance patient care

Enhance patient care

The design of the Philips Respironics V680 puts enhanced patient care at the forefront. Features designed to help protect patients from harmful events associated with pressure spikes, loss of ventilation or undetected critical alarms include:

 

  • Active control exhalation valve
  • Apnea modes
  • Auto-escalating alarm
  • Four-hour integrated battery

The V680 dynamic respiratory mechanics algorithm

 

The resistance (R) and compliance (C) calculations on the Respironics V680 ventilator system leverage advanced data acquisition and signal processing capabilities to allow pause-free, dynamic, breath-to-breath estimates of these parameters. Not only does the system estimate inspiratory and expiratory R and C, but it also estimates plateau pressure in both invasive and non-invasive applications. The dynamic respiratory mechanics measurements on the V680 ventilator approach the accuracy of measurements obtained with static methods requiring an inspiratory pause maneuver, while also avoiding the limitations of Least Squares curve-fitting methods.

 

Download the White Paper

Specifications Show all

Patient Types
Adult :
<gt/>20 kg
Pediatric :
5 to 20 kg
Modes: Single-limb Circuit
CPAP
(continuous positive airway pressure)
S/T
(spontaneous with timed backup)
PCV
(pressure control ventilation)
Apnea mode
(available in CPAP)
*AVAPS+
(average volume assured pressure support)
*PPV
(proportional pressure ventilation)
Modes: Dual-limb Circuit
A/C-VCV
(assist/control-volume control ventilation)
A/C-PCV
(assist/control-pressure control ventilation)
SIMV-VCV
(synchronized intermittent mandatory ventilation volume control ventilation)
SIMV-PCV
(synchronized intermittent mandatory ventilation pressure control ventilation)
PSV
(pressure support ventilation)
PRVC
(pressure regulated volume control)
Apnea mode
(available in SIMV and PSV)
Other Features
Ti/Ttot
0 to 99 %
Dyn Pplat (dynamic plateau pressure)
0 to 70 cm H₂O
F/VT (rapid shallow breathing index)
0 to 999
Pt. Leak (“unintentional” leak)
0 to 200L/min BTPS
Tot. Leak (total leak)
0 to 200L/min BTPS
Lung Mechanics Maneuvers
Static C&R:
1 to 200 mL/cmH2O
Static C:
5 to 1,000 cmH2O/L
Static E:
1 to 200 cmH2O/L/s
Static R:
0 to 70 cm H₂O
Static Pplat: P0.1 (P100)
0 to -50 cmH2O
MIP (Maximal Inspiratory Pressure)
0 to -50 cmH2O

Education and Resources

Philips Healthcare Can all patients benefit from NIV?

Philips Healthcare How do I set my ventilator for NIV

NIV patient interfaces and fitting guide

NIV patient interfaces and fitting guide